EMC Corporation
Corporate Headquarters
:
Hopkinton, MA 01748 -9103
1
-508 -435 -1000
www.emc.com
EMC Fibre Channel with
QLogic Host Bus Adapters in the
Windows Environment
P/N 300-001-164
REV A08
QLogic_Windows.book Page i Friday, May 27, 2005 3:53 PM
Przeglądanie stron 0
1 2 3 4 5 6 ... 105 106

Podsumowanie treści

Strona 1 - Windows Environment

EMC CorporationCorporate Headquarters:Hopkinton, MA 01748 -91031-508 -435 -1000www.emc.comEMC Fibre Channel withQLogic Host Bus Adapters in theWindow

Strona 2

11-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentIntroductionUnderstanding Persistent Binding in a Fabric EnvironmentPersistent bindin

Strona 3 - Contents

BB-6EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentThird-Party SoftwareQLogic_Windows.book Page 6 Friday, May 27, 2005 3:53 PM

Strona 4

TroubleshootingC-1CInvisible Body TagThis appendix contains information on troubleshooting problems. ◆ Problems and Solutions...

Strona 5 - HBA (TOE)

CC-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentTroubleshootingProblems and SolutionsProblem 1Error Message ID: 51 in event viewer wh

Strona 6 - Appendix C Troubleshooting

CProblems and SolutionsC-3TroubleshootingSolution Upgrade to the latest HBA driver. This was corrected for Windows 2000 in 8.2.2.25 and later drivers.

Strona 7

CC-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentTroubleshootingProblem 7When using SANSurfer 2.0.25 to update to BIOS 1.4x, you recei

Strona 8 - AVANT GARDE

EMC Fibre Channel with QLogic HBAs in the Windows Environmenti-1Aadapter BIOS 2-2Bbinding, persistent 1-2, 1-3BIOSadapter 2-2file 2-11updating 2-

Strona 9

EMC Fibre Channel with QLogic HBAs in the Windows Environmenti-2IndexHBA driver 2-14HBA, boot, replacing 3-35HBA, installing 2-3Iissues with boot s

Strona 10 - Introduction

1Understanding Persistent Binding in a Fabric Environment1-3Introduction\\PHYSICALDRIVE0, \\PHYSICALDRIVE1, and \\PHYSICALDRIVE2. The number is assign

Strona 11

11-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentIntroductionThe next figure shows the same host after the cable attached to HBA0 has

Strona 12

Installing and Configuring the HBA Driver2-12Invisible Body Tag This chapter describes the procedures for installing an EMC-approved QLogic host b

Strona 13 - Configuring the HBA

22-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverIntroductionThe procedure described here was

Strona 14

2Installing an HBA2-3Installing and Configuring the HBA DriverInstalling an HBAFollow the instructions included with your HBA. The HBA installs into a

Strona 15 - Installing an HBA

22-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA Driver4. Label each cable to identify the HBA and

Strona 16 - Clustering Configurations

2Installing an HBA2-5Installing and Configuring the HBA Driverfields to select the correct CX200-Series direct-connect dual-host cluster-compatible fi

Strona 17

22-6EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverIf later you wish to return the jumper(s) to

Strona 18

2Installing an HBA2-7Installing and Configuring the HBA Driver7. Enter a value for the loop ID and press ENTER.8. Press ESC to return to the Configura

Strona 19

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentiiCopyright © 2001–2005 EMC Corporation. All rights reserved.Updated June 2005EMC believe

Strona 20 - EMC HBA Settings

22-8EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverEMC HBA SettingsEMC requires configuring the

Strona 21 - Configuring NVRAM

2EMC HBA Settings2-9Installing and Configuring the HBA DriverConfiguring NVRAM for Stratus ftServersIf you have not received QLogic HBAs with the EMC

Strona 22

22-10EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverIgnore any steps that pertain to multiple a

Strona 23

2EMC HBA Settings2-11Installing and Configuring the HBA DriverUpdating WhileRunning WindowsTo update while running Windows, refer to QLogic SANSurfer

Strona 24 - HBA Data Rate

22-12EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA Driverfile name, note that some BIOS versions mig

Strona 25

2EMC HBA Settings2-13Installing and Configuring the HBA DriverSetting the Topology for QLA22xx/23xx and WindowsWhile using a QLA22xx or QLA23xx HBA fo

Strona 26 - Installing the HBA Driver

22-14EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA Driver12. Reboot the host.The preconfigured topol

Strona 27 - Windows 2003 STORPort Updates

2Installing the HBA Driver2-15Installing and Configuring the HBA DriverWhere to Find the DriverYou can find the Fibre Channel HBA driver:◆ on the QLog

Strona 28

22-16EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverInstallation Procedure for Windows 2000 and

Strona 29 - 18. Reboot the host

2Installing the HBA Driver2-17Installing and Configuring the HBA Driver16. The system again requests that you reboot the system. Select NO again.17. I

Strona 30

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentiiiPreface...

Strona 31

22-18EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverUpdating the HBA Driver in a Windows 2000 o

Strona 32

2Updating the HBA Driver in a Windows 2000 or Windows 2003 Host2-19Installing and Configuring the HBA Driver12. If prompted, click Yes to continue the

Strona 33 - Replacing an HBA

22-20EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverUpgrading to Windows 2003 from Windows 2000

Strona 34

2Replacing an HBA2-21Installing and Configuring the HBA DriverReplacing an HBAProcedure for Replacing a QLogic HBA in Stratus ftServers without Reboot

Strona 35

22-22EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA Driver10. Execute the following commands from a c

Strona 36

2Replacing an HBA2-23Installing and Configuring the HBA Driver10. Run symmask refresh to update the director profile tables (in cache) from the databa

Strona 37 - Boot Device

22-24EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverQLogic_Windows.book Page 24 Friday, May 2

Strona 38

Configuring an EMC Boot Device3-13Invisible Body Tag Windows hosts have been qualified for booting from EMC storage array devices interfaced throu

Strona 39

33-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceIntroductionWindows hosts have been qualified for booti

Strona 40 - Boot-from-SAN with MSCS

3Introduction3-3Configuring an EMC Boot Device◆ Storage Area Network service/upgrade procedures, such as firmware upgrades or hardware replacementsEMC

Strona 41 - Configuring the Boot BIOS

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentivContentsInstallation Procedure for Windows 2000 and Windows 2003 Hosts...

Strona 42

33-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceBoot Crashdump Save to Disk BehaviorIf you system is co

Strona 43

3Configuring a Symmetrix Boot Device3-5Configuring an EMC Boot DeviceConfiguring a Symmetrix Boot DeviceThis section describes how to install the Wind

Strona 44 - , type fs1: and

33-6EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device5. From the Configuration Settings menu, select Host Ad

Strona 45

3Configuring a Symmetrix Boot Device3-7Configuring an EMC Boot DeviceInstalling the Windows OS onto the Boot DeviceFollow the appropriate steps below

Strona 46 - <control>

33-8EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device1. Type drivers at the EFI shell prompt to display the

Strona 47

3Configuring a Symmetrix Boot Device3-9Configuring an EMC Boot Device2. To load the HBA risc code onto the HBA, type rw and press ENTER. The firmwar

Strona 48

33-10EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device3. The first two hex digits are the driver handle. To

Strona 49 - Procedure Flowchart

3Configuring a Symmetrix Boot Device3-11Configuring an EMC Boot Device5. Frame Size = 2048 (default)6. Select the topology for your configuration. In

Strona 50

33-12EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceProcedure to Install Windows Server 2003 on a Fibre Ch

Strona 51 - Requirements

3Configuring a CLARiiON Boot Device3-13Configuring an EMC Boot DeviceConfiguring a CLARiiON Boot DeviceThis section describes how to install a boot de

Strona 52 - Preparing the Storage System

vEMC Fibre Channel with QLogic HBAs in the Windows EnvironmentContentsReplacing a Boot HBA...

Strona 53 - Setting Up the HBA BIOS

33-14EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceRequirementsSatisfiedStartUnsatisfiedPrepare Storage

Strona 54 - Preparing the Fabric

3Configuring a CLARiiON Boot Device3-15Configuring an EMC Boot DeviceRequirementsThis section lists supported configurations, hardware and software re

Strona 55 - QLogic Corporation

33-16EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceMedia Requirements Required media includes the followi

Strona 56

3Configuring a CLARiiON Boot Device3-17Configuring an EMC Boot DeviceSetting Up the HBA BIOSAfter the HBA is installed in the host and the EMC array i

Strona 57 - Preparing the Server

33-18EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device9. Press ESC to exit the Fast!UTIL Options menu.10. Re

Strona 58 - Boot BIOS

3Configuring a CLARiiON Boot Device3-19Configuring an EMC Boot DeviceSoft Zoning These instructions let you configure the soft zoning as this setup re

Strona 59

33-20EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device3. Create a member alias for the boot HBA WWPN. Make s

Strona 60 - Installing Windows

3Configuring a CLARiiON Boot Device3-21Configuring an EMC Boot DevicePhysical Connectionof Only One SP Port tothe FabricIf the SP that owns the boot L

Strona 61

33-22EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device3. To disconnect all SCSI hard disk drives, unplug the

Strona 62

3Configuring a CLARiiON Boot Device3-23Configuring an EMC Boot DeviceDifferent HBA models may display different banners. Be sure to select CTRL-Q for

Strona 63

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentviContentsAppendix C TroubleshootingProblems and Solutions ...

Strona 64

33-24EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceWhen the QLogic BIOS banner (shown in step 1) appears,

Strona 65

3Configuring a CLARiiON Boot Device3-25Configuring an EMC Boot Device1. Insert a bootable Windows CD-ROM in the drive and reboot the system. If your s

Strona 66

33-26EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceThe Windows Server Setup dialog displays disk partitio

Strona 67

3Configuring a CLARiiON Boot Device3-27Configuring an EMC Boot DeviceIf your system prompts you to press any key to boot from CD-ROM, do not press a k

Strona 68

33-28EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceWhat Next? From here:◆ If you need to install multipat

Strona 69 - Starting a Fresh Installation

3Configuring a CLARiiON Boot Device3-29Configuring an EMC Boot Deviceoptions, depending on whether you want to disrupt the connectivity of the host:◆

Strona 70

33-30EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceConfiguring Additional Boot Port Name Entries in the B

Strona 71 - Replacing a Boot HBA

3Configuring a CLARiiON Boot Device3-31Configuring an EMC Boot Deviceother HBA you wish to configure has its own CTRL-Q BIOS prompt, reboot the server

Strona 72

33-32EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device9. Reboot the server.Trespassing the BootLUN Using atf

Strona 73 - Known Issues

3Configuring a CLARiiON Boot Device3-33Configuring an EMC Boot Device4. Reboot the server.Starting a Fresh InstallationTo start a fresh installation:◆

Strona 74

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentviiPrefaceConventions Used inThis GuideEMC uses the following conventions for notes, caut

Strona 75 - QLogic QLA4010 iSCSI

33-34EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceBoot Time and LUN AvailabilityBoot time is the amount

Strona 76

3Replacing a Boot HBA3-35Configuring an EMC Boot DeviceReplacing a Boot HBAIf a boot HBA fails, you can replace it with a new one as described in this

Strona 77

33-36EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceHow a Server Responds to Failure in the Boot LUN PathF

Strona 78

3Known Issues3-37Configuring an EMC Boot DeviceKnown IssuesBe aware of these issues:◆ QLogic BIOS 1.26 and later for QLA23xx and BIOS 1.79 and later f

Strona 79

33-38EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceQLogic_Windows.book Page 38 Friday, May 27, 2005 3:

Strona 80

Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)4-14Invisible Body Tag The QLA4010/4010C is an iSCSI HBA that provides PCI connectivi

Strona 81

44-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Installing the HBA Drive

Strona 82

4Installing the HBA Driver4-3Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)4. If Windows Plug-n-Play does not detect your QLA4010 HBA m

Strona 83

44-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Updating the HBA Driver

Strona 84

4Updating the HBA Driver in a Windows 2000 or Windows 2003 Host4-5Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)14. If the system reque

Strona 85

viiiEMC Fibre Channel with QLogic HBAs in the Windows EnvironmentPrefaceTypographical ConventionsEMC uses the following type style conventions in this

Strona 86

44-6EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Using the QLogic iSCSI S

Strona 87

4Using the QLogic iSCSI SANSurfer Application to Configure iSCSI Devices4-7Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)which host to

Strona 88

44-8EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Configuring iSNS setting

Strona 89

4Configuring iSNS settings for QLA40104-9Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)To update firmware on your iSCSI HBA, click the

Strona 90

44-10EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)The firmware will be lo

Strona 91

4Configuring iSNS settings for QLA40104-11Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)To configure your iSCSI targets, click the Targ

Strona 92

44-12EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)You may add as many tar

Strona 93 - HS40 (8839)

4Configuring iSNS settings for QLA40104-13Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)rity password. The default password is “config

Strona 94 - External Array

44-14EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Installing and Configur

Strona 95

4Installing and Configuring the QLA4010 iSCSI HBA to boot from an EMC Storage Array4-15Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)2.

Strona 96 - Manager Software or Agents

Introduction1-11Invisible Body TagThis document describes the procedures for installing an EMC-approved QLogic host bus adapter (HBA) into a Windows 2

Strona 97 - SANSurfer Version

44-16EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)15. Press ESC to return

Strona 98 - VERITAS Volume Manager 3.0

4Installing and Configuring the QLA4010 iSCSI HBA to boot from an EMC Storage Array4-17Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Pr

Strona 99 - VERITAS Foundation Suite 4.2

44-18EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Boot Time and LUN Avail

Strona 100 - Third-Party Software

Setting Up External Boot for IBM Blade Server HS40 (8839)A-1AInvisible Body TagThis appendix contains information on setting up external boot for IBM

Strona 101 - Troubleshooting

AA-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentSetting Up External Boot for IBM Blade Server HS40 (8839)Configuring an HS40 BladeCen

Strona 102 - Problems and Solutions

Third-Party SoftwareB-1BInvisible Body TagThis appendix contains additional information about third-party software used with Windows hosts.◆ QLogic SA

Strona 103 - Problem 6

BB-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentThird-Party SoftwareQLogic SANSurfer SANBlade ManagerStratus ftServers are not suppor

Strona 104 - Problem 8

BQLogic SANSurfer SANBlade ManagerB-3Third-Party SoftwareSANSurfer Version HistorySANSurfer versions include:◆ 2.0.21 — Initial ReleaseThe SANSurfer s

Strona 105

BB-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentThird-Party SoftwareVERITAS Volume Management Software for Windows Operating SystemsR

Strona 106

BVERITAS Volume Management Software for Windows Operating SystemsB-5Third-Party SoftwareVERITAS Volume Manager 3.1 and VERITAS DMPIf using PowerPath w

Komentarze do niniejszej Instrukcji